Gas Monitor
Total Analytical Solution 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
 
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
            sales@gasmonitors.com.my
   Home      Analox Instruments- Oxygen Sensor      Analox - Diving
 
 

Commercial Diving

AIR DIVING

 
 
 
 
ACG+
 
COMPRESSED AIR MONITOR FOR AIR DIVING
 
  • The ACG+ is a fixed or portable compressed air monitor which continually/periodically monitors for O2, CO2, CO, VOC and dew point.
  • It has a port to run an oil mist test and datalogs for 90 days. It is user maintainable and simple to calibrate.
  • Colorimetric tube testing and lab testing of diving gas is time-consuming, costly and only a spot check. 
  • The ACG+ compressed air monitor assists with compliance to standards such as EN12021
 
 
 
 
 
 
ADM ASPIDA
 
PANEL MOUNT OXYGEN ANALYSER
 
  • The ADM Aspida is a panel mounted analyser which measures oxygen.
  • There is also the option to add carbon dioxide monitoring to the ADM Aspida to make a dual monitor.
  • IMCA DO23 requires an oxygen monitor with audio alarms is used and COdetection methods are in place.
  • The ADM Aspida panel mount oxygen analyser has all bases covered to ensure IMCA compliance and diver safety.
 
 
HYP
 
PARTIAL PRESSURE O2 MONITOR
 
  • The O2 Portable is robust and provides a fast, accurate analysis of oxygen.
  • Weighing 200g, it can be taken anywhere.
  • Ensuring the oxygen content of diving gas cylinders is vital to ensure diver safety.
  • The O2 Portable is usually used by dive techs and tenders when checking gas cylinders on deck or in the gas storage room but is sometimes used on air panels in line.
 
 
CO CLEAR
 
CARBON MONOXIDE MONITOR FOR AIR DIVING
 
 
  • The CO Clear consists of a main sensor unit installed after the pressure has been regulated down to between 1 and 3BarG.
  • Optional extras include a relay which could be used to switch off the compressor or sound a remote alarm.
  • The unit has 2 alarm set points and audio/visual alarms.
  • Carbon monoxide (CO) is a dangerous and potentially lethal gas, the effects of which are increased with pressure.
  • It could enter the breathing gas from the compressor inlet or from issues relating to compressor maintenance.
 
 

 
O2NE+
 
HELIOX LEAK MONITOR
 
 
  • The O2NE+ heliox leak monitor comprises of a wall mounted main sensor unit and a repeater.
  • It is ranged from 0 to 25% and has 2 low audio/visual alarms.
  • The sensor has a very long life and calibration is only required every 12 months and can be achieved using certified air


 
 
 
 

SATURATION DIVING

 
 
 
SDA ROC MONITOR
 
  • The SDA ROC monitors the pressure of an occupied dive chamber and triggers an alarm if the rate of change is too high.
  • It does this by sampling readings from a depth sensor and applying an algorithm to smooth the effects of any sudden changes.
  • The SDA uses the readings to calculate the ROC value which it then compares against its pre-set alarm thresholds.
 
 
 
SDA HELIUM
 
  • The SDA He monitor provides a full-colour helium reading.
  • To achieve maximum accuracy, it must be used in conjunction with the SDA O2 with the networking option selected.
  • The alarm set point and calibration can be achieved using the front panel user interface and the SDA He provides audio/visual alarms, optional data-logging and 4-20mA/relay outputs
 
 
 
SDA TEMPERATURE & HUMIDITY
 
  • The SDA Temperature and Humidity monitor provides a full-colour display of both temperature and humidity.
  • The alarm set points can be adjusted using the front panel user interface and the SDA Temperature and Humidity provides audio/visual alarms, optional data-logging and 4-20mA/relay outputs (for 1 reading).
  • The monitor interfaces with a state of the art dual temperature and humidity probe.
  • The SDA Temperature and Humidity replaces the now obsolete Analox 4000 (Temperature) and Analox 7000 (Humidity).
 
 
 
 
 
 
SDA DEPTH
 
  • The SDA is a range of panel/rack mountable atmosphere monitors originally designed with the commercial diving in mind.
  • The SDA Depth monitor provides a full-colour display of the depth/pressure reading.
  • The alarm set points and calibration can be achieved using the front panel user interface and the SDA Depth provides audio/visual alarms, optional data-logging and 4-20mA/relay outputs.
  • The monitor interfaces with a pressure sensor provided by Analox or can be set up to interface with a third party sensor which provides a 4-20mA output.
  • The SDA Depth replaces the obsolete Analox 6000.
 
 


 
SDA CARBON DIOXIDE
 
  • The alarm set points and calibration on the SDA carbon dioxide monitor can be achieved using the front panel user interface and the SDA carbon dioxide provides audio/visual alarms, optional data-logging and 4-20mA/relay outputs.
  • The SDA carbon dioxide monitor interfaces with our state of the art digital 5S3 sensor.
  • The SDA carbon dioxide monitor replaces the now obsolete Analox 5001 and is fully retrofittable as a direct replacement.
 
 
 
SDA CARBON MONOXIDE
 
  • The SDA CO gas monitor reads results from a state-of-the-art, long-life digital electrochemical sensor.
  • These results are shown on a full colour display.
  • The alarm set points and calibration can be achieved using the front panel user interface and the SDA CO provides audio/visual alarms, optional data-logging and 4-20mA/relay outputs.
  • The SDA CO replaces the obsolete Analox 3000 and is fully retrofittable as a direct replacement.
 
 
 
SDA OXYGEN
 
  • The SDA O2 monitor provides a full-colour display of the oxygen reading taken from an electrochemical sensor.
  • The alarm set points and calibration can be achieved using the front panel user interface and the SDA O2 provides audio/visual alarms, optional data-logging and 4-20mA/relay outputs.
  • The monitor interfaces with our state of the art digital MEC sensor.
  • The SDA O2 oxygen monitor replaces the now obsolete Analox 1000 and is fully retrofittable as a direct replacement.
 
 
 
SDA DUAL OXYGEN
 
  • The dual SDA display has the ability to display O2 readings in both partial pressure (mbar O2) and as percent volume (%O2).
  • This will allow the end user to read the levels of Oxygen in either parameter without having to carry out any conversion calculations.
  • Intelligent sensors flag when calibration and sensor change are due
  • Designed with the latest digital technology
  • Easily configurable with with interchangeable sensors and software
  • Large, bright, full colour display
  • Datalogging option
  • Ethernet data output option
 
 
 
 
 

 


 

 
 
 
 
 

D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com 
           sales@gasmonitors.com.my