Gas Monitor
Total Analytical Solution 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
 
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
            sales@gasmonitors.com.my
   Home      Drager Single Gas Detector - Drager Pac 5500
 
 
 
 

Dräger Pac® 5500

 
 
Longer assignments are its speciality: the single gas instrument, Dräger Pac 5500, has no lifetime limitation, and is ideal for fast and accurate personal monitoring and the detection of carbon monoxide, hydrogen sulphide or oxygen.
 
Benefits

Tailor-made for tough industrial assignments

Dräger has specifically designed the Pac 5500 to meet tough industrial requirements. The shock-proof rubber casing offers reliable protection against external, mechanical influences and corrosive chemicals. The device meets the requirements of IP 68.
 
 
Reliable sensor technology featuring low operating costs

The Dräger Pac 5500 is equipped with the Dräger XXS sensor technology. These innovative sensors offer an extremely high performance, with fast reaction times of only ten seconds. The XXS sensors offer a long functional life of in excess of 4 years, including the Oxygen sensor, thus providing lower operating costs.
 

Event logger for 60 events

The Dräger Pac 5500 can store up to 60 events, along with their dates and times. Events such as activation and deactivation, gas and battery alarms, error modes, configuration adjustments, etc. can be loaded onto a PC via the infrared interface, and then can be analysed in detail. 
 
 

Safety in any situation

Within the device, the sensor has been specially positioned to allow gas access at both the top and the front of the device. Even when the unit is placed in a pocket, or the gas entry has been accidentally covered, it is still possible to take a reliable reading.
 
 

Large, language-free display

The large LCD display is particularly user friendly, and shows both the gas concentration and unit of measurement. It is also possible to activate the device's status display. In this case, the display only shows the concentration when the configured alarm threshold has been exceeded. Additional background lighting ensures that the display is always readable. 
 
 

Long calibration intervals

The Dräger XXS sensors are so stable that they only need to be adjusted every two years. 
 
 

Fast function test

Regular function tests are prescribed to ensure that the device always works flawlessly. Using the cost-efficient Dräger Bump Test Station, these tests can be performed within a matter of seconds. 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com 
           sales@gasmonitors.com.my