Home | | Michell- Condumax II | |
|
|
|
Condumax II On-Line Hydrocarbon Dew-Point Analyzer
Condumax II On-Line is a fully self-contained hydrocarbon dew point
analyzer, using the proven "Dark Spot" hydrocarbon dew point measurement
principle from the highly successful Condumax instrument. Combining a
hydrocarbon dew point cell and water dew point measurement in the same
compact and lightweight EExd enclosure, Condumax II On-Line requires
nothing more than mains power to operate.
Product Features
- Fully automatic on-line analysis
- Objective, highly repeatable measurements
- 0.5°C hydrocarbon dew-point accuracy
- Fundamental chilled mirror principle
- Patented detection technique
- Self-cleaning
- No purge or cooling gas required
- Optional water dew-point analysis
- Modbus RTU
- IECEx, ATEX, CCSAUS and GOST Ex certifications
|
Condumax II Transportable Water & Hydrocarbon Dew-Point Analyzer
Transportable natural gas dew-point analyzer system for operation in the field. Suitable for IEC
Zone 1 or 2 hazardous area, NEC Class I, Division 1 Groups B, C, D.
A complete transportable natural
gas dew-point analysis system for field spot-check measurements. Periodic online operation
when located in a temperature maintained analyzer house. Measurements and functionality are instantly
accessible through integrated alphanumeric display and touch-glass HMI interface including log of dew-point
readings for operator review.
Product Features
- Field transportable self-contained dew-point analyzer system
- Simultaneous HC and water dew-point measurements in a single analyzer
- Automatic objective measurements by industry proven principles
- Parameter specific sensors ensure continuity of HC and water dew-point readings
- Self-contained sample handling, conditioning and analysis package
- 0.5°C HC dew-point accuracy
- Fundamental cooled mirror principle
|
Condumax II and OptiPEAK TDL600
Combined Hydrocarbon Dew Point and Moisture Analyzer for Natural Gas Transmission Pipeline Quality
Hydrocarbon dew point (HCDP) and moisture are key quality parameters to
ensure the quality of pipeline transmission gas. With the combined
Condumax II and OptiPEAK TDL600 analyzer system pipeline operators have
the assurance of the most widely accepted automatic hydrocarbon dew
point analyzer together with the latest development of spectroscopic
moisture measurement techniques in a single, convenient analyzer system.
Moisture
- Measurement range: 1ppmV to 1000ppmV
- Measurement technology: Tuneable Diode Laser Spectroscopy
- Latest generation of TDLAS – moisture measurements are independent to changes in background gas composition
- Class-leading accuracy ±1ppmV even with widely varying gas compositions
Hydrocarbon dew point
- HCDP measurement range: up to ∆ 55K measurement depression from main unit operating temperature
- HCDP measurement technology: direct photo-detection of hydrocarbon condensate
- Largest installation fleet across six continents
General
- Low maintenance
- Easy to install with a small footprint
|
|
|
|
|
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor,
Malaysia
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com