Gas Monitor
Total Analytical Solution 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
 
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
            sales@gasmonitors.com.my
   Home      RKI S2 Series
 
 
 
S2 Series

Diffusion Sensor/Transmitter

 
The RKI S2 series gas sensor/transmitters are highly reliable and very cost effective for the detection of common gas hazards. The S2 series are available for LEL, H2 Specific (LEL, and ppm), Oxygen, H2S, CO, and for a variety of toxic gases. The transmitters for LEL, H2 Specific, Oxygen, H2S, CO2, and Carbon Monoxide are explosion-proof with flame arrestors, and approved for use in hazardous areas (Class l, Groups B, C, D). An optional non-explosion proof version is available for oxygen, H2S, CO, and CO2 in non-hazardous atmospheres. LEL sensors are available using catalytic bead and infrared technologies.

The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in Class I, Div. 2 hazardous locations. Sensors available for NH3, SO2, PH3, AsH3, and HCN.

The S2 transmitters can be used either indoors or outdoors. The flame arrestors for the explosion-proof versions utilize a patented coating which make them water repellent. Splash guards are also available for use in very wet environments. An optional stainless steel junction box is available for corrosive environments.

All of the S2 transmitters are designed to interface with RKI controllers, or with PLC/DCS systems.

 

Features

  • Available gases include
    LEL, H2S, CO, PPM H2, and CO2
    Toxic gases include NH3, SO2, HCN, and more
  • Infrared sensor for combustibles and CO2
  • Hydrogen-Specific now available
  • Patented water repellent sensor coating
  • 4-20 mA output
  • Explosion proof construction
  • Optional stainless steel junction box
 
 
Applications
  • Petrochemical Plants
  • Refineries
  • Gas Plants
  • Offshore Drilling Platforms
  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • Chemical storage buildings
 
 
 
EXPLOSION PROOF SPECIFICATIONS
 
 
 
2 MOS and Infrared CO2 CH4 HC versions are also available

Explosion Proof

LEL
General Purpose

LEL
H2 Specific

O2
Oxygen

H2S Hydrogen Sulfide

CO Carbon Monoxide

Part # 65-2405RK 65-2451RK 65-2322RK 65-2331RK 65-2336RK
65-2405RK-05 65-2451RK-05
Sensor Catalytic Galvanic cell Electrochemical
Measuring Range 0-100% LEL 0-100% LEL (H2 Specific) 0-25% Vol. 0-100 ppm 0-300 ppm
Lower Detectable Limit (LDL) 2% of full scale 0.1% Vol. 2% of full scale
Max Current Draw (24VDC) 200 mA (power wires) 25 mA (signal wires)
3 wires
20 mA max, 2 wires
Response Time (T-90) 30 Seconds 20 Seconds 20 Seconds 45 Seconds 30 Seconds
Accuracy +/- 5% of full scale (0.5% volume for oxygen)
Life
Expectancy
2 to 3 years with normal exposure to flammable gas 3-5 years with normal service 2-3 years with normal service

Operating Environment

Location Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.
Temperature -40°F to 167°F -40°C to 75°C -4°F to 113°F -20°C to 45°C -40°F to 104°F -40°C to 40°C 23°F to 104°F -5°C to 40°C
Humidity 0 - 99% RH, non condensing

Housing

Housing J Box Cast aluminum explosion proof, optional stainless steel J-box available
Sensor Stainless steel explosion proof

Controls

Zero Sets transmitter output to 4 mA with zero output from sensor
Span Sets transmitter output to proper level when span gas is applied
Output 4 - 20 mA signal
Operating Voltage 11 VDC to 30 VDC 19-30VDC (250 OHMS impedance max)
Approvals 65-2405RK UL 65-2451RK UL CSA NRTL
65-2405RK-05
C CSA US
65-2451RK-05
C CSA US
Controllers Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410, and 800, also PLC and DCS systems
Warranty One year materials and workmanship

Explosion Proof

MOS

IR


H2 PPM
Hydrogen

CO2
Carbon Dioxide

CH4
Methane

HC
Hydrocarbons

Part # 65-2442RK-1000
65-2442RK-2000
65-2396RK-02
65-2396RK-03
65-2396RK-05
65-2396RK-10
65-2394RK-CH4 65-2394RK-HC
Sensor Metal oxide
semiconductor
Infrared
Measuring Range 0-1000 ppm
0-2000 ppm
0 - 5000 ppm
0 - 5% Vol.
0 - 50% Vol.
0 - 100% Vol.
0-100% LEL
Lower Detectable Limit (LDL) 2% of full scale
Max Current Draw (24VDC) 200 mA (power wires) 25 mA (signal wires) 3 wires 60 mA (power wires) 25 mA (signal wires) 3 wires
Response Time
(T-90)
45 Seconds 30 Seconds
Accuracy ± 10% of
reading or
± 5% of full scale
± 5% of reading or
± 2% of full scale
Life
Expectancy
5 years plus with normal service 5 years plus with normal service

Operating Environment

Location Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.
Temperature -40°F to 167°F
-40°C to 75°C
-4°F to 122°F -20°C to 50°C
Humidity 0 - 99% RH, non condensing
Housing
Housing J Box Cast aluminum explosion proof, optional stainless steel J-box available
Sensor Stainless steel explosion proof

Controls

Zero Sets transmitter output to 4 mA with zero output from sensor
Span Sets transmitter output to proper level when span gas is applied
Output 4 - 20 mA signal
Operating Voltage 19 VDC to 30 VDC 11 VDC to 30 VDC
Approvals UL C UL US
Controllers Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410, and 800, also PLC and DCS systems
Warranty
 
 
 
 

Direct Interface with Beacon 110 / 200 / 410 / 800 Controllers

S2 Wiring Matrix

S2 Transmitter
Number of Wires to Controller
Maximum Distance to Controller
18 AWG wire
16 AWG wire
14 AWG wire
LEL / IR / CO2
3
2500 ft.
5,000 ft.
8,000 ft.
Oxygen
2
2500 ft.
5,000 ft.
8,000 ft.
H2S
2
2500 ft.
5,000 ft.
8,000 ft.
CO
2
2500 ft.
5,000 ft.
8,000 ft.
Toxics
2
2500 ft.
5,000 ft.
8,000 ft.

 
 
NON EXPLOSION PROOF SPECIFICATIONS
 
 
 

on-Explosion Proof

O2 Oxygen

H2S Hydrogen Sulfide

CO Carbon Monoxide

Toxics See chart below

CO2 Carbon Dioxide

Part # 65-2321RK 65-2330RK 65-2335RK See chart
below
65-2397RK-02
65-2397RK-03
65-2397RK-05
65-2397RK-10
Sensor Galvanic cell Electrochemical Infrared
Measuring Range 0-25% Vol. 0-100 ppm 0-300 ppm See chart
below
0 - 5000 ppm
0 - 5% Vol.
0 - 50% Vol.
0 - 100% Vol.
Lower Detectable Limit (LDL) 0.1% Vol. 2% of full scale
Accuracy +/- 5% of full scale (0.5% volume for oxygen)
Life Expectancy 2 years normal
service
2 to 3 years with normal service 5 years plus with
normal service
Response Time (T-90) 20 Seconds 45 Seconds 30 Seconds 60 Seconds 30 Seconds

Operating Environment

Location Indoor Class I, Div. 2
Temperature -4°F to 122°F -20°C to 50°C 14°F to 104°F -10°C to 40°C -4°F to 122°F -20°C to 50°C
Humidity 0 - 99% RH non condensing 5-95% RH 0 - 99% RH
non condensing

Housing

Housing J-Box Cast aluminum, explosion-proof
Sensor Plastic or aluminum
Controls
Zero Sets transmitter output to 4 mA with zero output from sensor
Span Sets transmitter output to 20 mA with full scale output from sensor
Operating Voltage 19 VDC to 30 VDC
Output 4-20 mA signal
Controllers Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410, and 800, also PLC and DCS systems
Warranty

 
S2 toxic sensor

Non Explosion Proof Toxic Assemblies

Ordering Information

Part Number

Gas

Range

65-2340RK-ASH3 Arsine (AsH3) 0 - 1.5 ppm
65-2340RK-NH3 Ammonia (NH3) 0 - 75 ppm
65-2340RK-Cl2 Chlorine (Cl2) 0 - 3.00 ppm
65-2340RK-HCN Hydrogen Cyanide (HCN) 0 - 15 ppm
65-2340RK-PH3 Phosphine (PH3) 0 - 1.00 ppm
65-2340RK-SO2 Sulfur Dioxide (SO2) 0 - 6.00 ppm

Direct Interface with Beacon 110 / 200 / 410 / 800 Controllers

S2 Wiring Matrix

S2 Transmitter
Number of Wires to Controller
Maximum Distance to Controller
18 AWG wire
16 AWG wire
14 AWG wire
LEL / IR / CO2
3
2500 ft.
5,000 ft.
8,000 ft.
Oxygen
2
2500 ft.
5,000 ft.
8,000 ft.
H2S
2
2500 ft.
5,000 ft.
8,000 ft.
CO
2
2500 ft.
5,000 ft.
8,000 ft.
Toxics
2
2500 ft.
5,000 ft.
8,000 ft.

 
 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com 
           sales@gasmonitors.com.my