| Home | | Bacharach- PCA 3 | |
|
|
|
|
PCA 3
Affordable, Best-In-Class Portable Combustion Analyzer
Busy technicians and boiler contractors who need to
ensure safe operating conditions, determine combustion efficiency and
perform emissions testing rely on Bacharach’s PCA®3. This
lightweight handheld instrument is the industry’s first advanced
portable combustion analyzer with a full color graphic display for
superior visibility and user-friendly interface. Super bright
backlighting, zoom display feature, dimming mode function and the most
sensor configuration in its class provides the user with best-in-class
instrumentation. In addition to the included Oxygen (O2) and Carbon Monoxide (CO) sensors, the PCA®3 can be ordered with CO (high), Nitric Oxide (NO), Nitrogen Dioxide (NO2) and Sulfur Dioxide (SO2) sensors or the sensors can be added in the field without down time, using the B-Smart® pre-calibrated sensor options.
PCA®3 is designed for on-demand or semi-continuous
sampling of light industrial, institutional, commercial and residential
furnaces, boilers and appliances. With sturdy metal gas and draft
connectors and rugged construction plus simple operation and maintenance
the PCA®3 is the new workhorse of the industry.
Bacharach's unique B-Smart® Sensor Exchange Program will deliver new B-Smart®
Sensors right to the user. Just a simple "pop out and pop in"
replacement of the sensor permits self calibration with no gas or guess
work required! Providing the quickest and easiest calibration options to
date, the B-Smart® Sensors assures accurate performance with no downtime.
Features & Benefits
- Analyzer Functionality
- Directly measures and displays Flue Gas Oxygen (O2), Carbon Monoxide (CO), Stack Temperature, Draft, Differential Pressure, Combustion Air Temperature
- Optionally measures and displays Nitric Oxide (NO), Nitrogen Dioxide (NO2) and Sulfur Dioxide (SO2)
- Calculates and displays Combustion Efficiency (EFF), Excess Air (EA), Carbon Dioxide (CO2), NOx and Oxygen reference values
- Ten selectable fuels plus the ability to custom-load fuels
- Stores 1,000 tests (500 in memory and 500 in logged memory)
- Smart Sensors
- Instrument includes a pre-calibrated Oxygen (O2) sensor and a pre-calibrated B-Smart® Carbon Monoxide (CO) sensor
- Unique B-Smart® sensor technology saves downtime and calibration costs
- Best-in-Class sensor configuration flexibility allows purchased configurations or simple upgrade in the field
- Sensor options include pre-calibrated B-Smart® NO, NO2, SO2 and CO high sensors
- Graphic Display
- 320 x 240 pixel full color graphic display for superior visibility
- Super-bright backlighting and zoom capability to ensure
effortless readability in any low light boiler and furnace room
situations
- Easily change language parameters to display in formation in English, French or Spanish
- Dimming mode function helps extend battery life
- Rugged Design and Construction
- Sturdy metal gas and draft connectors for added durability in the field
- Tough ABS housing with rugged rubberized over-molding and protective boot with magnet
PCA® 3 Reporting Packages:
- 2 Gases (O2, CO) Part No. 0024-8447
- 3 Gases (O2, CO, NO) Part No. 0024-8448
- 3 Gases (O2, CO, CO high) Part No. 0024-8449
- 3 Gases (O2, CO, SO2) Part No. 0024-8450
- 4 Gases (O2, CO, NO, NO2) Part No. 0024-8451
- 4 Gases (O2, CO, NO, SO2) Part No. 0024-8452
- 4 Gases (O2, CO, NO, CO high) Part No. 0024-8453
All reporting packages include printer
Specifications:
pecifications:
| Measurement Ranges |
North American Version |
| Primary/Ambient Air Temperature |
-4° to 999°F |
| Stack Temperature |
-4° to 2192°F |
| Oxygen |
0 to 20.9% |
| Carbon Monoxide (H2 Compensated) |
0 to 4,000 ppm |
| Carbon Monoxide, (High Range) |
4,001 to 20,000 ppm |
| Nitric Oxide |
0 to 3,000 ppm |
| Nitrogen Dioxide |
0 to 500 ppm |
| Sulfur Dioxide |
0 to 5,000 ppm |
| Pressure/Draft |
-72 to +72 inwc |
| Calculated Ranges |
Combustion Efficiency |
0.1 to 100% |
| Excess Air |
1.0 to 250% |
| Carbon Dioxide (Dry Basis) |
0 to Fuel Dependent Maximum |
| NOx (NO + NO2) |
0 to 3,500 ppm |
| NOx referenced to % O2 |
0 to 9,999 ppm |
| CO referenced to % O2 |
0 to 9,999 ppm |
| NO referenced to % O2 |
0 to 9,999 ppm |
| NO2 referenced to % O2 |
0 to 9,999 ppm |
| SO2 referenced to % O2 |
0 to 9,999 ppm |
| Accuracy |
Oxygen |
± 0.3% O2 (Flue Gas) |
| Stack or Flue Gas Temperature |
± 4°F between 32 and 255°F
(± 2°C between 0 and 124°C) |
± 6°F between 256 and 480°F
(± 3°C between 125 and 249°C) |
± 8°F between 481 and 752°F
(± 4°C between 250 and 400°C) |
| Primary-air/Ambient Temperature |
± 2°F between 32 and 212°F
(± 1°C between 0 and 100°C) |
| Pressure/Draft |
± 2% Reading or 0.02 inwc -1 to 10 inwc |
| ± 3% of Reading between ± -40 and ± 40 inwc |
| CO |
± 5% of Reading or ± 10 ppm in the range of 0-2000 ppm CO |
| ± 10% of Reading between 2001 to 4,000 ppm |
| NO |
± 5% of Reading or ± 5 ppm whichever is greater between 0 to 2000 ppm NO |
| NO2 |
± 5% of Reading or ± 5 ppm whichever is greater between 0-500 ppm NO2 |
| SO2 |
± 5% of Reading or ± 10 ppm whichever is greater between 0-2000 ppm SO2 |
Specifications: (continued)
| Memory |
500 Complete Combustion Test Records |
| Logged Memory |
500 Complete Logged Combustion Test Records |
| Selectable Fuels |
Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, Bagasse and Digester Gas |
| Size |
9"H x 3"W x 2.5" (22.9 cm x 7.6 cm x 6.3 cm) |
| Weight |
1.4 lbs (0.6 kg) |
| Power Source |
Four Disposable AA Alkaline Batteries. Optional Universal AC Adapter (100 to 240 Volts at 47 to 63 Hz) |
| Display |
Full Color Graphic Display (320 x 240 pixels) |
| Warm Up Time |
60 Second Total Warm Up Time (sensors are checked and autozeroed during warm up) |
Ordering Information
| Model Number |
Part Number |
Sensor |
Sensor |
Sensor |
Sensor |
Printer |
| PCA®3 225 |
0024-8440 |
O2 |
CO |
|
|
|
| PCA®3 235 |
0024-8441 |
O2 |
CO |
NO |
|
|
| PCA®3 245 |
0024-8442 |
O2 |
CO |
CO (high) |
|
|
| PCA®3 255 |
0024-8443 |
O2 |
CO |
SO2 |
|
|
| PCA®3 265 |
0024-8444 |
O2 |
CO |
NO |
NO2 |
|
| PCA®3 275 |
0024-8445 |
O2 |
CO |
NO |
SO2 |
|
| PCA®3 285 |
0024-8446 |
O2 |
CO |
NO |
CO (high) |
|
| PCA®3 225 Kit |
0024-8447 |
O2 |
CO |
|
|
X |
| PCA®3 235 Kit |
0024-8448 |
O2 |
CO |
NO |
|
X |
| PCA®3 245 Kit |
0024-8449 |
O2 |
CO |
CO (high) |
|
X |
| PCA®3 255 Kit |
0024-8450 |
O2 |
CO |
SO2 |
|
X |
| PCA®3 265 Kit |
0024-8451 |
O2 |
CO |
NO |
NO2 |
X |
| PCA®3 275 Kit |
0024-8452 |
O2 |
CO |
NO |
SO2 |
X |
| PCA®3 285 Kit |
0024-8453 |
O2 |
CO |
NO |
CO (high) |
X |
Instrument Comes Complete With: Hard Carry Case, 12" Probe and Hose
Assembly, Factory Calibrated and Installed Sensors, Protective Boot
w/Magnet, Replacement Filter Element (pkg. of 3), Instruction Manual, 4
'AA' Batteries, USB Cable, Fyrite® User Software and a 2-Year Warranty.
All instruments can be upgraded to include combinations of CO(high), NO, NO2 and SO2.
Replacement Parts & Accessories
| Part Number |
Description |
| 0024-1541 |
B-Smart® CO (H2 Compensated) Sensor |
| 0024-1542 |
B-Smart® CO (high range) Sensor |
| 0024-1545 |
B-Smart® NO Sensor |
| 0024-1544 |
B-Smart® NO2 Sensor |
| 0024-1543 |
B-Smart® SO2 Sensor |
| 0024-0788 |
Replacement O2 Sensor |
| 0024-0789 |
Replacement CO Sensor |
| 0024-0881 |
Replacement NO Sensor |
| 0024-0997 |
Replacement CO (high range) |
| 0024-0998 |
Replacement SO2 Sensor |
| 0024-1027 |
Replacement NO2 Sensor |
| 0024-1400 |
IrDA Printer w/Disposable Batteries (comes with Reporting Pkg. Kit) |
| 0024-1310 |
Printer Paper (5 rolls) |
| 0006-8733 |
Printer Paper (1 roll) |
| 0024-1254 |
Universal AC Power Adapter (110-240V) |
| 0007-1644 |
Replacement Filter Element (pkg. of 3) |
| 0024-7224 |
Compact Sample Conditioner |
| 0024-3004 |
Replacement Probe Assembly (North American) |
| 0024-3053 |
Replacement Probe Assembly (European) |
| 0024-1124 |
20 ft. Hose Extension with Sample, Draft and Thermocouple Lines |
| 0024-1470 |
Fyrite® User Software |
| 0021-7006 |
True Spot® Smoke Tester |
|
|
|
|
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor,
Malaysia
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
sales@gasmonitors.com.my |
|
|
|
|
|