Warns against hazardous gas concentrations
Every
working day places the highest demands on gas monitoring. The device
reliably warns against hazardous concentrations of carbon monoxide,
hydrogen sulphide (including a Low Concentration option), oxygen, carbon
dioxide, sulphur dioxide, chlorine, hydrogen cyanide, ammonia, nitrogen
dioxide, nitrogen monoxide, phosphine and organic vapours.
Simple calibration and configuration
The bump
test mode and sensitivity calibration can be selected via a
password-protected menu. The fresh air calibration can be optimally
protected using a password. The device is equipped with an infrared
interface and can be connected to a PC via a communication cradle in
order to activate the desired functions or download stored data.
Innovative miniature sensors
The innovative
Dräger XXS sensors react quickly and produce reliable measurement
results. Very short diffusion paths inside the device, as well as the
sensors' rapid electrochemical reactions, ensure that any gas-related
dangers are displayed as soon as they occur. For maximum safety, the
sensor is positioned inside the housing such as to allow gas to reach it
from above and from the front. This guarantees flawless measurement,
even when the gas entry has been accidentally obstructed.
5-year guarantee option
Dräger offers an optional 5-year warranty for the hydrogen sulphide, oxygen and carbon monoxide monitors.
Robust and long-lasting
Protective rubber
ensures that the casing of the Dräger Pac 7000 is particularly
shock-proof. The device meets the strict dust and water protection
requirements specified in IP 68. The electromagnetic resistance has also
been optimised. Dräger has designed the Dräger Pac 7000 for unlimited
lifetime. When needed, the sensors can be simply replaced.
Fast bump tests with the Dräger Bump Test Station
To
perform an automatic function test with a known gas concentration
within a matter of seconds, the device is simply inserted into the
Dräger Bump Test Station. The display informs the user if the bump test
(function test) was successful. If the test is not performed within a
certain time frame, the device can be set-up to deactivate itself.
Triple alarm for extra safety
As soon as the
adjustable alarm thresholds are exceeded, or values fall below the
configured oxygen concentration, the Dräger Pac 7000 immediately issues
an audible, visual and vibrating alarm. In addition, the device is also
equipped with adjustable TWA and STEL alarms. The user is also warned
when the battery is low or a functional error has occurred.