Home | | GFG- Microtector II G460 | |
|
|
|
The multi-gas detector Microtector II G460 has been specifically
developed for meeting the requirements of daily work. It is the lightest
and smallest gas detector in its class, easy to use and designed
according to ergonomic principles.
The innovative multi-gas detector G460 passes the performance test
and is certified according to EN 60079-29-1 (explosive gases), EN 50104
(oxygen) and EN 45544 (toxic gases).
The standard version of G460 detects O2, H2S, CO, CO2 and combustible
gases in particular. Additional sensors are available for NH3, HCl, PH3,
HCN, NO, NO2, SO2 and a variety of other gases. Thus, you can arrange
your GfG gas detector to fit your exact requirements.
One single GfG infrared sensor is enough to simultaneously measure CO2,
the lower explosion limit (LEL) and up to 100% vol. of combustible
gases. This innovative technology is exclusively available at GfG.
The wear-free and extremely durable GfG infrared sensors considerably
reduce your future expenditure for maintenance and replacement of
sensors.
For increasing the user’s safety, this device detects carbon dioxide by
means of the selective infrared measuring technology (NDIR). The IR sensors
provide long-term stable detection values. Unlike electrochemical
sensors, the IR measuring technology is not subject to cross sensitivity
from toxic hydrogen sulphide. Furthermore, the expected sensor life of a
GfG infrared sensor corresponds to the expected service life of the gas
detector. Thus in the medium-term, there is no need to replace used-up
or contaminated electrochemical sensors.
Comprehensive protection is additionally provided by a PID
(photoionization detector) detecting volatile organic compounds.
Familiar substances containing VOCs include solvents, paint thinner and
nail polish remover as well as the gases and vapours associated with
fuels such as gasoline, diesel, heating oil or kerosene. Specific toxic
substances such as benzene, butadiene, hexane, toluene, xylene and many
others are reliably detected. For most VOCs, however, the occupational
exposure limit value is achieved long before readings reach a
concentration high enough to trigger a combustible range alarm. The PID
provides additional protection here.
Microtector II G460 has a robust casing. Due to the high-class rubber
coating, the device is extremely shockproof and water resistant (IP67).
Depending on the installed sensor equipment, the operating time is up to
30 hours such that its usage for the entire working days can be
assured. For power supply, either batteries or rechargeable batteries
can be used. The gas detector Microtector II G460 is particularly small
and the lightest device in its class. Due to this, users consider
wearing the device as particularly convenient and non-disturbing.
The innovative design and exceptional functionality of this device were
honoured with one of the internationally most coveted prized for
product design, the red dot design award and the GIT SICHERHEIT AWARD.
An innovative alarm system has been developed to reliably warn of
possible gas hazards. In case of gas hazard, the display changes its
colour – depending on the hazard level – like a traffic light to green,
orange or red. In addition, a circumferential LED strip flashes with the
respective colour. A high performance audible alarm is also in noisy
environments louder than any other ambient noise. The big coloured
graphic display is reversible by 180° such that an easy reading is
assured even when wearing the device on the body. The integrated zoom
function can be used to enlarge the display at a push of a button. This
ensures an easy reading of the measurement values even in difficult
situations and both hands are kept free.
Rechargeable NiMH or alkaline batteries which can be exchanged quickly
and easily are available for providing the power supply. Their operating
time is up to 30 hours. In combination with the NiMH battery pack
equipped with EX-protected LED lights, the device can additionally be
used as a bright flash light. With the help of the charging tray, the
battery packs can be charged comfortably. However, charging is also
possible using the docking station, test station or the vehicle charging
cable for 12 V and 24 V.
Apart from operation in normal diffusion mode, the gas detector can
optionally be equipped with the electrical pump G400-MP2. The pump has
an own power supply, flow monitoring and communicates with the gas
detector.
Whether it's a simple functional test or a complete documentation,
tried and tested solutions are at your disposal. The mobile test station
TS400 and automatic test and calibrating station DS400 are the ideal
supplements to save money, time and efforts. Fast reacting GfG high
performance sensors and a sophisticated pump system enable the lowest
gas consumption.
- IR sensor for CO2 and combustible gases (LEL and 100% vol.) for a non-toxic atmosphere
- PID sensor for direct reading of toxic volatile organic compounds (VOCs)
- Smart sensor technology for easily exchangeable sensors
- Integrated Ex-protected light
- Vibration alarm
- Battery compartment instead of rechargeable battery mode as option
- Adaptable electrical pump
- Longlife data logger (45 years)
|
|
|
|
|
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor,
Malaysia
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
sales@gasmonitors.com.my |
|
|
|
|