|
|
Oxygen Analyzers and Thermal Conductivity Analyzers
Reliable, low maintenance Oxygen Analyzers ideal for trace oxygen measurement
Oxygen Analyzers
XTP601 Series
Oxygen Analyzer for Safe or Hazardous Areas
- General purpose or ATEX, IECEx, CCSAUS, TC, TR & Ex hazardous area certified models
- Ranges available: 0–0.5% up to 0–50% & 20, 80 or 90–100%
- Touch-screen display allows calibration or adjustment without the need for a hot works permit
- Intrinsic error (accuracy) is better than 1% full scale
|
XZR500
Combustion Control Oxygen Analyzer
- Reliable and repeatable measurements
- Simple to maintain, easy to calibrate
- Robust design
- Quick and easy to install
- Simple to use
- No chance of thermal shock to sample cell
- Long life zirconia cell
|
XZR400
Oxygen Analyzer
- Fast response time
- Simple and easy operation
- Low maintenance and cost of ownership
- No need for reference air
- Barometric pressure compensation
- Multiple Outputs available from 4-20 mA, RS485 Modbus RTU and RS232
|
XZR200
Oxygen Analyzer
- Configurable outputs: 4-20 mA and 0 to 10 V DC or RS232 comms interface
- Cycling 3.3 V DC logic output allows direct monitoring of the O2 sensor for diagnostic purposes
- Can be calibrated in normal air (20.7% O2) or in any other known O2 concentration
- Selectable output filtering allows fast and dynamic or slow and stable output
- Externally triggered automatic or manual calibration
|
- Measures 0 - 25% O2 in Flue Gas
- Sample temperature up to +700°C
- Barometric pressure and temperature sensors included
- MODBUS as standard
- Single or Dual 4-20 mA outputs
- User configurable relays
- Easy to swap sensor, requiring no special tools
- Sensor exchange program
|
XGA301
Industrial Gas Analyzer
- Sensor choices from zirconia, galvanic electrochemical, infrared and ceramic impedance technologies
- Variable speed pump (optional)
- Zirconia sensor cleaning facility which can be operated at any time during use
- Intuitive HMI with back-lit display
- Two fully-programmable alarms
- 2 x voltage outputs and 2 x 4–20 mA outputs
- Digital RS232 output
|
XTC601
monitoring hydrogen cooled generators
- Suitable for use in ATEX, IECEx, TC TR Ex & CCSAUS certified Hazardous Areas
- Monitors all three phases of hydrogen cooled electricity generators - normal running, purging and maintenance
- Remotely change the measurement phase to match your maintenance schedule
- Range indication via 4-20 mA output
- Touch-screen display allows calibration or adjustment without the need for a hot works permit
|
XTC601
Binary Gas Analyzer
- Suitable for use in ATEX, IECEx, TC TR Ex & CCSAUS certified Hazardous Areas
- Optional status LED’s following NAMUR standard
- Compact and rugged design with an EExd enclosure and 4-20 mA output
- Touch-screen display allows calibration or adjustment without the need for a hot works permit
- Accuracy of better than ±2% full scale
- IP66 rated enclosure
- Low cost of ownership due to minimal maintenance
|
PCR
Portable Calibration Rig
- Blends two or three gases from Air, O2, N2, CO2, CH4
& H2
- Select series MFC’s programmed with all the above
gases
- Flame arrestors fitted for additional safety
- Quick-Connect fittings, wheels and retractable handle
for ease of use
- Rugged case that is water-tight
(with lid closed & locked)
|
|
|
|
|
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor,
Malaysia
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
sales@gasmonitors.com.my |
|
|
|
|