   Home      Air Particle Counters
         
 
 
 
 
 
 
 

Air Particle Counters

 
 

Handheld Air Particle Series

 
 
 
 
 
 
 
MET ONE HHPC 2+ Handheld
 
  • Part Number : 2089310-03
  • 2 channel
  • Particle Size Analysis Range 0.5 - 5 μm
 
 
Platform APC Instruments
Industry Standards 21 CFR Part 11, ISO 14644-1:2015, CE, FCC
Particle Size Analysis Range 0.5 - 5 μm
Coincidence Loss 10% at 4,000,000 particles/ft³
Sample Volume 5 µm
Throughput 2.83 L per minute
Interfaces & Protocols USB Host (v1.1), USB Client (v1.1)
Data Storage 10,000 records
Battery Lithium Ion (rechargeable) battery
Battery Operating Time

10+ hours (typical use) / minimum 5.5 hours (continuous sampling)

Battery Recharge Time 3.5 hours
Pump Accuracy ±5% Flow Rate
Pump Repeatability ±5% Flow Rate
Zero Count Conforms to JIS B9921 (1 count or less in 5 min; 95% UCL)
Counting Efficiency 50% at 0.5 µm (100% for particles > 0.75 µm)
Count Alarms, Display & Cycles Raw counts: N/CF, N/CM, N/L in cumulative or differential mode, User-defined alarm counts
Label Locations Alphanμmeric Location Names
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Humidity Restrictions < 95% non-condensing
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Operating System Windows IE, Safari and Firefox
Resolution 320 x 240
Display 3.5" high-resolution (320 x 240) color display
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Height 5.3 cm(2.1 in)
Color Gray
Package Quantity 1
 
 
 
 
 
 
 
 
MET ONE HHPC 3+ Handheld with Case
 
  • Part Number2089310-02
  • 3 Channel | with Case
  • Particle Size Analysis Range 0.3 - 10 μm
 
 
Platform APC Instruments
Performance ISO 14644-1 class 5 compliant 0.3 µm samples in a minute
Industry Standards 21 CFR Part 11, ISO 14644-1:2015, CE, FCC
Particle Size Analysis Range 0.3 - 10 μm
Coincidence Loss 10% at 4,000,000 particles/ft³
Sample Volume 10 µm
Throughput 2.83 L per minute
Interfaces & Protocols USB Client (v1.1), USB Host (v1.1)
Data Storage 10,000 records
Battery Lithium Ion (rechargeable) battery
Battery Operating Time 10+ hours (typical use) / minimum 5.5 hours (continuous sampling)
Battery Recharge Time 3.5 hours
Pump Accuracy ±5% Flow Rate
Pump Repeatability ±5% Flow Rate
Zero Count Conforms to JIS B9921 (1 count or less in 5 min; 95% UCL)
Counting Efficiency 50% at 0.3 µm (100% for particles > 0.45 µm)
Count Alarms, Display & Cycles Raw counts: N/CF, N/CM, N/L in cumulative or differential mode, User-defined alarm counts
Label Locations Alphanμmeric Location Names
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Humidity Restrictions < 95% non-condensing
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Operating System Windows IE, Safari and Firefox
Resolution 320 x 240
Display 3.5" high-resolution (320 x 240) color display
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Height 5.3 cm(2.1 in)
Color Gray
Package Quantity 1
 
 
 
 
 
 
MET ONE HHPC 3+ Handheld
 
  • Part Number: 2089310-06
  • 3 channel
  • Particle Size Analysis Range 0.3 - 10 μm
 
 
Platform APC Instruments
Performance ISO 14644-1 class 5 compliant 0.3 µm samples in a minute
Industry Standards 21 CFR Part 11, ISO 14644-1:2015, CE, FCC
Particle Size Analysis Range 0.3 - 10 μm
Coincidence Loss 10% at 4,000,000 particles/ft³
Sample Volume 10 µm
Throughput 2.83 L per minute
Interfaces & Protocols USB Client (v1.1), USB Host (v1.1)
Data Storage 10,000 records
Battery Lithium Ion (rechargeable) battery
Battery Operating Time 10+ hours (typical use) / minimum 5.5 hours (continuous sampling)
Battery Recharge Time 3.5 hours
Pump Accuracy ±5% Flow Rate
Pump Repeatability ±5% Flow Rate
Zero Count Conforms to JIS B9921 (1 count or less in 5 min; 95% UCL)
Counting Efficiency 50% at 0.3 µm (100% for particles > 0.45 µm)
Count Alarms, Display & Cycles User-defined alarm counts, Raw counts: N/CF, N/CM, N/L in cumulative or differential mode
Label Locations Alphanμmeric Location Names
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Humidity Restrictions < 95% non-condensing
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Resolution 320 x 240
Display 3.5" high-resolution (320 x 240) color display
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Height 5.3 cm(2.1 in)
Color Gray
Package Quantity 1
 
 
 
 
MET ONE HHPC 3+ Handheld with Case
 
  • Part Number2089310-08
  • 3 channel | with Case
  • Particle Size Analysis Range0.5 - 5 μm
 
Platform APC Instruments
Industry Standards 21 CFR Part 11, ISO 14644-1:2015, CE, FCC
Particle Size Analysis Range 0.5 - 5 μm
Coincidence Loss 10% at 4,000,000 particles/ft³
Sample Volume 5 µm
Throughput 2.83 L per minute
Interfaces & Protocols USB Client (v1.1), USB Host (v1.1)
Data Storage 10,000 records
Battery Lithium Ion (rechargeable) battery
Battery Operating Time 10+ hours (typical use) & minimum 5.5 hours continuous sampling
Battery Recharge Time 3.5 hours
Zero Count Conforms to JIS B9921 (1 count or less in 5 min; 95% UCL)
Counting Efficiency 50% at 0.5 µm (100% for particles > 0.75 µm)
Count Alarms, Display & Cycles Raw counts: N/CF, N/CM, N/L (cumulative/differential mode); user-defined alarm counts
Label Locations Alphanμmeric Location Names
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Resolution 320 x 240
Display 3.5" high-resolution (320 x 240) color display
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Height 5.3 cm(2.1 in)
Color Gray
Package Quantity 1
 
 
 
 
MET ONE HHPC 3+ Handheld
 
  • Part Number2089310-07
  • Description3 channel
  • Particle Size Analysis Range0.5 - 5 μm
 
Platform APC Instruments
Industry Standards 21 CFR Part 11, ISO 14644-1:2015, CE, FCC
Particle Size Analysis Range 0.5 - 5 μm
Coincidence Loss 10% at 4,000,000 particles/ft³
Sample Volume 5 µm
Throughput 2.83 L per minute
Interfaces & Protocols USB Client (v1.1), USB Host (v1.1)
Data Storage 10,000 records
Battery Lithium Ion (rechargeable) battery
Battery Operating Time 10+ hours (typical use) / minimum 5.5 hours (continuous sampling)
Battery Recharge Time 3.5 hours
Pump Accuracy ±5% Flow Rate
Pump Repeatability ±5% Flow Rate
Zero Count Conforms to JIS B9921 (1 count or less in 5 min; 95% UCL)
Counting Efficiency 50% at 0.5 µm (100% for particles > 0.75 µm)
Count Alarms, Display & Cycles User-defined alarm counts, Raw counts: N/CF, N/CM, N/L in cumulative or differential mode
Label Locations Alphanμmeric Location Names
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Humidity Restrictions < 95% non-condensing
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Resolution 320 x 240
Display 3.5" high-resolution (320 x 240) color display
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Height 5.3 cm(2.1 in)
Color Gray
Package Quantity 1
 
 
 
 
 
 
MET ONE HHPC 6+ Handheld with Case and Charge Cradle
 
  • Part Number2089311-01
  • Description6 channel | with Case and Charge Cradle
  • Particle Size Analysis Range0.3 - 10 μm
 
Platform APC Instruments
Performance ISO 14644-1 class 5 compliant 0.3 µm samples in a minute
Industry Standards 21 CFR Part 11, CE, FCC, ISO 14644-1:2015
Particle Size Analysis Range 0.3 - 10 μm
Coincidence Loss 10% at 4,000,000 particles/ft³
Sample Volume 10 µm
Throughput 2.83 L per minute
Interfaces & Protocols USB Client (v1.1), USB Host (v1.1)
Data Storage 10,000 records
Battery Lithium Ion (rechargeable) battery
Battery Operating Time 10+ hours (typical use) / minimum 5.5 hours (continuous sampling)
Battery Recharge Time 3.5 hours
Pump Accuracy ±5% Flow Rate
Pump Repeatability ±5% Flow Rate
Zero Count Conforms to JIS B9921 (1 count or less in 5 min; 95% UCL)
Counting Efficiency 50% at 0.3 µm (100% for particles > 0.45 µm)
Count Alarms, Display & Cycles Raw counts: N/CF, N/CM, N/L in cumulative or differential mode, User-defined alarm counts
Label Locations Alphanμmeric Location Names
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Humidity Restrictions < 95% non-condensing
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Operating System Windows IE, Safari and Firefox
Software Supports data browsing via Ethernet on Windows Internet Explorer, Safari, and Firefox
Resolution 320 x 240
Display 3.5" high-resolution (320 x 240) color display
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Height 5.3 cm(2.1 in)
Color Gray
Package Quantity 1
 
 
 
 
MET ONE HHPC 6+ Handheld with Case
 
  • Part Number2089310-01
  • 6 Channel with Case
  • Particle Size Analysis Range0.3 - 10 μm
 
Platform APC Instruments
Performance ISO 14644-1 class 5 compliant 0.3 µm samples in a minute
Industry Standards 21 CFR Part 11, ISO 14644-1:2015, CE, FCC
Particle Size Analysis Range 0.3 - 10 μm
Coincidence Loss 10% at 4,000,000 particles/ft³
Sample Volume 10 µm
Throughput 2.83 L per minute
Interfaces & Protocols USB Client (v1.1), USB Host (v1.1)
Data Storage 10,000 records
Battery Lithium Ion (rechargeable) battery
Battery Operating Time 10+ hours (typical use) / minimum 5.5 hours (continuous sampling)
Battery Recharge Time 3.5 hours
Pump Accuracy ±5% Flow Rate
Pump Repeatability ±5% Flow Rate
Zero Count Conforms to JIS B9921 (1 count or less in 5 min; 95% UCL)
Counting Efficiency 50% at 0.3 µm (100% for particles > 0.45 µm)
Count Alarms, Display & Cycles Raw counts: N/CF, N/CM, N/L in cumulative or differential mode, User-defined alarm counts
Label Locations Alphanμmeric Location Names
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Humidity Restrictions < 95% non-condensing
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Operating System Windows IE, Safari and Firefox
Resolution 320 x 240
Display 3.5" high-resolution (320 x 240) color display
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Height 5.3 cm(2.1 in)
Color Gray
Package Quantity 1
 
 
 
 
MET ONE HHPC 6+ Handheld with Charge Cradle
 
  • Part Number2089311-05
  • 6 channel | with charge cradle
  • Particle Size Analysis Range0.3 - 10 μm
 
Platform APC Instruments
Package Quantity 1
Environmental Conditions Indoor Environment
Humidity Restrictions < 95% non-condensing
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Color Gray
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Sterile Non-Sterile
Autoclavable No
Nonpyrogenic Yes
Sample Volume 10 µm
 
 
 
 
MET ONE HHPC 6+ Handheld
 
  • Part Number2089310-05
  • 6 channel
  • Particle Size Analysis Range0.3 - 10 μm
 
Platform APC Instruments
Performance ISO 14644-1 class 5 compliant 0.3 µm samples in a minute
Industry Standards 21 CFR Part 11, ISO 14644-1:2015, CE, FCC
Particle Size Analysis Range 0.3 - 10 μm
Coincidence Loss 10% at 4,000,000 particles/ft³
Sample Volume 10 µm
Throughput 2.83 L per minute
Interfaces & Protocols USB Client (v1.1), USB Host (v1.1)
Data Storage 10,000 records
Battery Lithium Ion (rechargeable) battery
Battery Operating Time 10+ hours (typical use) / minimum 5.5 hours (continuous sampling)
Battery Recharge Time 3.5 hours
Zero Count Conforms to JIS B9921 (1 count or less in 5 min; 95% UCL)
Counting Efficiency 50% at 0.3 µm (100% for particles > 0.45 µm)
Count Alarms, Display & Cycles Raw counts: N/CF, N/CM, N/L (cumulative/differential mode); user-defined alarm counts
Label Locations Alphanμmeric Location Names
Environmental Conditions Indoor Environment
Temperature Range Operating temperature range: 10°C to 40°C, Storage temperature range: -10°C to 50°C
Humidity Restrictions < 95% non-condensing
Power Requirements 100-240 VAC, 50/60 Hz, 1.0 A
Resolution 320 x 240
Display 3.5" high-resolution (320 x 240) color display
Operating Modes Semi-automated, manual, controlled by operator
Autoclavable No
Nonpyrogenic Yes
Weight 0.7 kg(1.5 lb)
Width 27 cm(10.6 in)
Depth 10 cm(3.9 in)
Height 5.3 cm(2.1 in)
Color Gray
Package Quantity 1
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 


 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593