Accessories

 
 
 

Portable Pump
Low diffusion long-life pump
 
 
  • Suitable for Class 1 Division 2 Group CD areas.
  • Suitable for trace oxygen analysis of ambient and negative pressure samples.
 
 
 
 
Sample Pump
Fixed Mount Low diffusion long-life pump
 
 
  • CSA approved for Class 1 Division 2 Group CD areas.
  • Suitable for trace oxygen analysis of ambient and negative pressure samples.
 
 
 
 
 
 
Demister II
Water Separation Unit
 
 
  • Brings warm wet samples to ambient temperature
  • Large surface area for high efficiency
  • Condenses water vapor and drains it back to the source
  • No need for coalescing filters

 
LRP w/ Regulator
Liquid Rejection Probe
 
 
  • Membrane filter stops liquids from reaching the analyzer
  • No bypass required – no loss of sample
  • Condensation returns to sample source – no maintenance required
 
 
 

 
LRP w/ Demister
Liquid Rejection Probe
 
 
  • Membrane filter stops liquids from reaching the analyzer
  • No bypass required – no loss of sample
  • Condensation returns to sample source – no maintenance required


 
Extreme Weather Enclosure
Protection from the elements and extreme temperatures
 
  • Enclosure for 2010BR/210BR/3010BR analyzers for extreme conditions
 
 
 

 
Protective Carry Case
 

 
  • Provides protection for the 1000RS/3000RS/111 series of portable analyzers in harsh environments.
 


Interface III
Computer Interface
 
 
  • Self-configuring universal software package for PCs. Communicates with all AMI analyzers and allows access to all their many features.
 

 
Single Channel Display
Display unit for model 60 and 65
 
 
  • Works with any model 60/65 probe
  • Accepts either voltage or current input signals
  • Displays oxygen from 0.00% to 100%
  • isolated 4-20mA output
  • Single range operation
 
 
 
 
LRP
Liquid Rejection Probe
 
 
  • Membrane filter stops liquids from reaching the analyzer
  • No bypass required – no loss of sample
  • Condensation returns to sample source – no maintenance required
 
 
 
Flexible High Pressure
Sample Tubing

  • Low-diffusion flexible tubing for connecting calibration gas cylinders to analyzers.
  • O ring seals avoid wear on gas fittings
 
Auxiliary Power Adapter
 

 
  • Charges 1000RS/3000RS portable analyzer from a cigarette lighter accessory.
 
 
 
 
 
 
 
 