| Home | | Drager- Pac 6000 | |
|
|
|
Dräger Pac® 6000
The Dräger Pac® 6000 disposable personal gas detector measures CO, H2S, SO2 or O2 reliably
and precisely, even in the toughest conditions. The robust design,
quick sensor response times, and a powerful battery ensure maximum
safety for up to two years with virtually no maintenance required.
Strong performance for maximum safety
You can rely on the Dräger Pac 6000: The personal single gas
detection device warns against hazardous concentrations of carbon
monoxide, hydrogen sulfide, sulfur dioxide or oxygen with precision and
reliability.
Powerful sensors with a very low t-90 response
time ensure quick reactions. The Pac 6000 is versatile thanks to its
wide measurement range. For example, the CO sensor measures
concentrations from 1 to 1,999 ppm, and the H2S sensor from 0.4 to 100 ppm.
Easy handling thanks to clear user guidance
The D-Light indicates whether the functionality of the device has been
tested and that it is ready to use. The housing is also designed with
your safety in mind: each sensor variant of the Dräger Pac 6000 features
a clearly visible color coding, thereby minimizing the chance of
mistakes.
Robust design – even for the toughest conditions
The Pac 6000 can easily handle even extreme conditions: depending on
the sensor, temperatures from -40 °C to 55 °C and air pressures between
700 and 1,300 mbar can be tolerated.
A membrane filter
protects the sensor from foreign matter such as dust and liquids. The
shock-proof, chemical-resistant housing meets the requirements specified
in the IP68 standard rating.
Accessories
Calibration Adapter
- The communication module (including USB cable) is used to connect the
equipment to the configuration and evaluation software.
- The module is
also used for the manual bump test or manual calibration.
- The test gas
is introduced to the Pac device through the gas inlet or outlet.
|
Dräger Gas Vision Software
- Save measurement results and professionally configure gas detection
devices – all that is possible with the tailor-made Dräger software.
|
Calibration gas and accessories
- Strictly to rule: For the safe operation of devices, applicable
regulations and statutory provisions are to be met and complied with.
- Therefore, regular calibrations and function tests are necessary.
- Available for that are different systems, which meet a wide range of
calibration requirements.
|
|
|
|
|
|
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor,
Malaysia
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
sales@gasmonitors.com.my |
|
|
|
|
|