Dräger Pac® 6500
The robust Dräger Pac® 6500 is your reliable companion under tough conditions. The personal single-gas detection device measures CO, H2S, SO2 or O2 quickly and precisely. Quick sensor response times and a replaceable battery also ensure safety.
Strong performance for maximum safety
You can rely on the Dräger Pac 6500: the personal single-gas
detection device warns against hazardous concentrations of carbon
monoxide, hydrogen sulfide, sulfide dioxide or oxygen with precision and
reliability.Powerful sensors with a very low t-90 response time
ensure quick reactions. The Pac 6500 is versatile thanks to its wide
measurement range. For example, the CO sensor measures concentrations
from 1 to 1,999 ppm, and the H2S sensor from 0.4 to 100 ppm.
Easy handling thanks to clear user guidance
The D-Light indicates whether functionality of the device has been
tested and whether it is ready to use. The housing is also designed with
your safety in mind: each sensor variant of the Dräger Pac 6500
features clearly visible color coding, thereby minimizing the chance of
mistakes.
Robust design – even for the toughest conditions
The Pac 6500 is easily handled in even extreme conditions. Depending
on the sensor, temperatures from -40 °C to 55 °C and air pressures
between 700 and 1,300 mbar can be tolerated.A membrane filter
protects the sensor from foreign matter such as dust and liquids. The
shock-proof, chemical-resistant housing meets the requirements specified
in the IP68 standard rating.
User-friendly display with all important information
The large display clearly indicates the respective gas concentration.
Other important information, such as the battery capacity, is also
displayed. The bright backlighting ensures that all values are clearly
legible in the dark.
360° alarm with various functions
If the Dräger Pac 6500 measures hazardous gas concentrations, it sets
off an audible, visual and perceptible vibrating alarm. Two bright,
flashing LEDs on the top and bottom of the device ensure that the alarm
is easily visible from all sides. The acoustic signal reaches a volume
of 90 dB. The display can show the peak concentration measured at any
given moment. Earlier alarms registered can also be retrieved at a later
time, even if they have been acknowledged.The Pac 6500 with
oxygen sensor has two additional alarm thresholds in addition to the
standard alarm threshold settings. This provides an additional level of
safety as a pre-alarm, in addition to the main alarm, can be set for
both oxygen enriched and oxygen deficient atmospheres.
Data logger and event logger for analyses and reports
The Dräger Pac 6500 logs concentrations and events along with the date
and time. The data can be loaded on a PC via an interface and processed
further there
Economical operating costs
All versions of the Pac 6500 are equipped with extremely durable
DrägerSensors and a powerful battery. Neither the sensor nor the battery
need to be changed over the minimum two-year maintenance-free service
life of the H2S, SO2 and CO versions.The
Pac 6500 is protected against water, dust and other foreign bodies by a
special membrane filter. When the filter becomes heavily soiled in use,
you can quickly and easily replace it yourself. The device is then ready
to use again right away.
Fast function test saves time and money
Function tests and calibrations can be carried in the Dräger X-dock®
calibration station. The automatic bump tests in the X-dock are a
cost-efficient and convenient solution thanks to the short test duration
and the extremely low consumption of test gas. The Pac 6500 is simply
placed in the bump test station and automatically selects the correct
setting.
Accessories
Calibration Adapter
- The communication module (including USB cable) is used to connect the
equipment to the configuration and evaluation software.
- The module is
also used for the manual bump test or manual calibration.
- The test gas
is introduced to the Pac device through the gas inlet or outlet.
|
Calibration gas and accessories
- Strictly to rule: For the safe operation of devices, applicable
regulations and statutory provisions are to be met and complied with.
- Therefore, regular calibrations and function tests are necessary.
- Available for that are different systems, which meet a wide range of
calibration requirements.
|
Dräger Gas Vision Software
- Save measurement results and professionally configure gas detection
devices – all that is possible with the tailor-made Dräger software.
|
|
|
|
|
|
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor,
Malaysia
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
sales@gasmonitors.com.my |
|
|
|
|
|