Tube tip holder722
Safe storage of broken tips
The
Tube tip holder doubles as a detector tube tip breaker and a storage
receptacle for up to 260 broken tips, thereby preventing glass fragments
from scattering.
Rubber caps DTP-1-20/DTP-2-20
Safety caps for tubes
Reusable
rubber caps can be attached to the broken edges of the detector tubes
as an extra precautionary safety measure. Blue caps can be used with the
largest size detector tubes (outer diametre of 7mm) and pink ones with
all other tubes. One (1) package contains 20 caps.
No.DTP-1-20(blue)
large-diametre tubes for tube nos. 1HH, 2HT, 2HH, 4HT, 31B (blue)
No.DTP-2-20(pink)
for all type of gas detector tubes except the above
Extension hoses 351A-5/351A-10/351A-30
Measuring in manholes, storage tanks, etc.
Extension
hoses are available to be attached to the inlet of the gas sampling
pump (Model GV-100) and used for remote downward measurement in confined
spaces, such as manholes, tanks, etc.
* For twin tube operation, order the Extension hose guard rubber
(No.358) . When the extension hose tip needs to be replaced, order the
Replacement extension hose guard rubber (No.359) .
351A-5 (for 5m long), 351A-10 (for 10m long), 351A-30 (for 30m long)
Hot probe/Hot probe holder 340/345A
Accurate measuring of hot gases
The
hot probe is a cooling device for measuring hot gases (60 to 600ºC /
140 to 1112 ºF) such as exhaust from vehicles and incinerators by
cooling them down to normal temperatures. The stability of the device is
enhanced when it is secured with the hot probe holder (No.345A)
Hot probe holder (Model 345A) can not be used with Twin-tubes and Oxygen tube No. 31B.
Extension pole 350BP-2
Horizontal and vertical measuring
Made
of lightweight fiberglass and weighing only 590g, the extension
sampling pole has a compact body (62.5 cm) for easy portability and can
be extended to a maximum length of 2.8m.
Twin Tube Holder GV500
Damage protection for twin tubes
The twin tube holder protects twin tubes from drop and damage or prevents injury to the user during a measurement.
One hand operation adapter GV-700
GV-700 can maintain a vacuum of 50mL or 100mL in the pump body.this
allows the user to attatch the appropriate tube to pump ,and then in
situations where it is necessary , to take the sample using one hand. In
the body of the Adapter there is a samll rod which can be moved in or
out quite easily with one finger.
Boring (drill) rod 361
Kimitsu™Contaminated Vadose Zone Assessment technique
Contaminant distribution can be easily and accurately determined.
A hole is drilled in the ground with the boring rod, and the
contaminants present in the gas in the hole are measured; by taking
measurements at multiple points on a site the exact distribution of
contaminants can be assessed.
Extension pole for sub-surface sampling 360
Kimitsu™ Contaminated Vadose Zone Assessment technique
Contaminant distribution can be easily and accurately determined.
A hole is drilled in the ground with the boring rod, and the
contaminants present in the gas in the hole are measured; by taking
measurements at multiple points on a site the exact distribution of
contaminants can be assessed.
Dositube holder 710
The passive dositube can then be positioned in the worker's breathing
zone where it can be attached with a holder and collar clip (separately
available : Art.No.710) and the amount of individual exposure can be
measured.
Smoke tester kit 500
Determining gas flow direction in smoke
Break
off both ends of the smoke tube and attach a rubber squeeze bulb to one
end of the tube. When the bulb is squeezed, a chemical reaction
produces white smoke. This smoke makes the air flow (in ventilation
systems/ducts, etc.) visible. A single tube can be repeatedly used for
about 50 tests.
|
|
|
|
|