Gas Monitor
Total Analytical Solution 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
 
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
            sales@gasmonitors.com.my
   Home      Gastec- Accessories
               
 
 
 
 
 
 
 
 
 
 
 

Tube tip holder722

Safe storage of broken tips

The Tube tip holder doubles as a detector tube tip breaker and a storage receptacle for up to 260 broken tips, thereby preventing glass fragments from scattering.

 
 
 
 
 
 
 
 
 
 

 

Rubber caps DTP-1-20/DTP-2-20

Safety caps for tubes

Reusable rubber caps can be attached to the broken edges of the detector tubes as an extra precautionary safety measure. Blue caps can be used with the largest size detector tubes (outer diametre of 7mm) and pink ones with all other tubes. One (1) package contains 20 caps.

No.DTP-1-20(blue)
large-diametre tubes for tube nos. 1HH, 2HT, 2HH, 4HT, 31B (blue)
No.DTP-2-20(pink)
for all type of gas detector tubes except the above

 
 
 
 
 
 
 
 
 

Extension hoses 351A-5/351A-10/351A-30

Measuring in manholes, storage tanks, etc.

Extension hoses are available to be attached to the inlet of the gas sampling pump (Model GV-100) and used for remote downward measurement in confined spaces, such as manholes, tanks, etc.
* For twin tube operation, order the Extension hose guard rubber (No.358) . When the extension hose tip needs to be replaced, order the Replacement extension hose guard rubber (No.359) .

351A-5 (for 5m long), 351A-10 (for 10m long), 351A-30 (for 30m long)

 
 
 
 
 
 
 
 
 
 

Hot probe/Hot probe holder 340/345A

Accurate measuring of hot gases

The hot probe is a cooling device for measuring hot gases (60 to 600ºC / 140 to 1112 ºF) such as exhaust from vehicles and incinerators by cooling them down to normal temperatures. The stability of the device is enhanced when it is secured with the hot probe holder (No.345A)

Hot probe holder (Model 345A) can not be used with Twin-tubes and Oxygen tube No. 31B.

 
 
 
 
 
 
 
 
 
 
 
 
 

Extension pole 350BP-2

Horizontal and vertical measuring

Made of lightweight fiberglass and weighing only 590g, the extension sampling pole has a compact body (62.5 cm) for easy portability and can be extended to a maximum length of 2.8m.

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Twin Tube Holder GV500

Damage protection for twin tubes

The twin tube holder protects twin tubes from drop and damage or prevents injury to the user during a measurement.

 
 
 
 
 
 
 
 
 
 
 
 
 
 

One hand operation adapter GV-700

GV-700 can maintain a vacuum of 50mL or 100mL in the pump body.this allows the user to attatch the appropriate tube to pump ,and then in situations where it is necessary , to take the sample using one hand. In the body of the Adapter there is a samll rod which can be moved in or out quite easily with one finger.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Boring (drill) rod 361

Kimitsu™Contaminated Vadose Zone Assessment technique

Contaminant distribution can be easily and accurately determined.

A hole is drilled in the ground with the boring rod, and the contaminants present in the gas in the hole are measured; by taking measurements at multiple points on a site the exact distribution of contaminants can be assessed.
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Extension pole for sub-surface sampling 360

Kimitsu™ Contaminated Vadose Zone Assessment technique

Contaminant distribution can be easily and accurately determined.
A hole is drilled in the ground with the boring rod, and the contaminants present in the gas in the hole are measured; by taking measurements at multiple points on a site the exact distribution of contaminants can be assessed.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Dositube holder 710

The passive dositube can then be positioned in the worker's breathing zone where it can be attached with a holder and collar clip (separately available : Art.No.710) and the amount of individual exposure can be measured.
 
 
 


 
 
 
 
 
 
 
 
 

Smoke tester kit 500

Determining gas flow direction in smoke

Break off both ends of the smoke tube and attach a rubber squeeze bulb to one end of the tube. When the bulb is squeezed, a chemical reaction produces white smoke. This smoke makes the air flow (in ventilation systems/ducts, etc.) visible. A single tube can be repeatedly used for about 50 tests.

 
 
 
 
 
 
 
 
 
 
 

 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com 
           sales@gasmonitors.com.my