Gas Monitor
Total Analytical Solution 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
 
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
            sales@gasmonitors.com.my
   Home      Michell- Condumax II
              
 
 
 
 
 
 
 
 
 
 

Condumax II On-Line Hydrocarbon Dew-Point Analyzer

Condumax II On-Line is a fully self-contained hydrocarbon dew point analyzer, using the proven "Dark Spot" hydrocarbon dew point measurement principle from the highly successful Condumax instrument. Combining a hydrocarbon dew point cell and water dew point measurement in the same compact and lightweight EExd enclosure, Condumax II On-Line requires nothing more than mains power to operate. 
 
 

Product Features

  • Fully automatic on-line analysis
  • Objective, highly repeatable measurements
  • 0.5°C hydrocarbon dew-point accuracy
  • Fundamental chilled mirror principle
  • Patented detection technique
  • Self-cleaning
  • No purge or cooling gas required
  • Optional water dew-point analysis
  • Modbus RTU
  • IECEx, ATEX, CCSAUS and GOST Ex certifications
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Condumax II Transportable Water & Hydrocarbon Dew-Point Analyzer

Transportable natural gas dew-point analyzer system for operation in the field. Suitable for IEC Zone 1 or 2 hazardous area, NEC Class I, Division 1 Groups B, C, D.

A complete transportable natural gas dew-point analysis system for field spot-check measurements. Periodic online operation when located in a temperature maintained analyzer house. Measurements and functionality are instantly accessible through integrated alphanumeric display and touch-glass HMI interface including log of dew-point readings for operator review.
 
 

Product Features

  • Field transportable self-contained dew-point analyzer system
  • Simultaneous HC and water dew-point measurements in a single analyzer
  • Automatic objective measurements by industry proven principles
  • Parameter specific sensors ensure continuity of HC and water dew-point readings
  • Self-contained sample handling, conditioning and analysis package
  • 0.5°C HC dew-point accuracy
  • Fundamental cooled mirror principle
 
 
 
 
 
 
 
 
 
 

Condumax II and OptiPEAK TDL600

Combined Hydrocarbon Dew Point and Moisture Analyzer for Natural Gas Transmission Pipeline Quality

 
Hydrocarbon dew point (HCDP) and moisture are key quality parameters to ensure the quality of pipeline transmission gas. With the combined Condumax II and OptiPEAK TDL600 analyzer system pipeline operators have the assurance of the most widely accepted automatic hydrocarbon dew point analyzer together with the latest development of spectroscopic moisture measurement techniques in a single, convenient analyzer system.
 
 

Moisture

  • Measurement range: 1ppmV to 1000ppmV
  • Measurement technology: Tuneable Diode Laser Spectroscopy
  • Latest generation of TDLAS – moisture measurements are independent to changes in background gas composition
  • Class-leading accuracy ±1ppmV even with widely varying gas compositions
 
 

Hydrocarbon dew point

  • HCDP measurement range: up to ∆ 55K measurement depression from main unit operating temperature
  • HCDP measurement technology: direct photo-detection of hydrocarbon condensate
  • Largest installation fleet across six continents
 

General

  • Low maintenance
  • Easy to install with a small footprint
 
 
 
 
 
 
 
 
 
 
 

 
 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com 
           sales@gasmonitors.com.my