Gas Monitor
Total Analytical Solution 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
 
Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com
            sales@gasmonitors.com.my
   Home      Status- FGD14 Series
 
 
 
 
 
 

FGD14 Series

Safe Area Gas Detectors - Mains/DC Powered

Warning - These gas detectors must only be used in applications where there is no risk of potentially explosive gases being present or of them being created through industrial processes or other activities within the area concerned. 
The FGD14 series are stand-alone gas detectors with a front panel display of the gas level. The detectors contain 2 control relays that can be activated via user definable alarm set points; the relay contacts can then be used to control external equipment. 
Communication with other equipment such as a PC may be acheived by using the inbuilt RS232 communications port. An audible/visual remote unit is also provided with the detector 
 
Models are available for powering from either:- 
A mains supply of between 85 and 265 volts ac. 
A DC power supply from 9 to 30 volts. 
 
Typical applications for the FGD14 series are in:- 
Water purification processes. 
Food preparation and/or storage. 
Car parks. 
Swimming pools. 
Medical applications.
 
 

Ammonia Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Standard ranges 0-100ppm or 0-1000ppm NH3. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. 
  • Mains and dc powered versions available.
 
 
 

Carbon Dioxide Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Ranges available from 0-500ppm up to 0-100% volume CO2 - see 'Order Codes' below for standard ranges. 
  • Temperature compensated infrared sensor. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. 
  • Mains and dc powered versions available.
 
 
 

Carbon Monoxide Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Standard range 0-500ppm, other ranges available up to 1000ppm CO. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. Mains and dc powered versions available.
 
 
 
 

Chlorine Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

 

Features

  • Range 0-20ppm Cl2. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. Mains and dc powered versions available.
 
 
 
 

Ehylene Oxide Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Range 0-100ppm ETO. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. Mains and dc powered versions available.
 
 

Hydrogen Chloride Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology

Features 

 
  • Standard range 0-30ppm HCl. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. 
  • Mains and dc powered versions available.
 
 
 

Hydrogen Sulphide Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Standard range 0-50ppm, other ranges available up to 0-200ppm H2S. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. 
  • Mains and dc powered versions available.
 
 

Nitric Oxide Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Range 0-100ppm NO. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. Mains and dc powered versions available.
 
 
 
 

Nitrogen Dioxide Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Range 0-20ppm NO2. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. 
  • Mains and dc powered versions available.
 
 
 
 

Oxygen Deficiency Safe Area Fixed Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Range 0-25% O2. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. 
  • Mains and dc powered versions available.
 
 
 
 
 

Sulphur Dioxide Safe Area Fixed Gas Detector FGD14 Series, Mains or DC Powered Using Electrochemical Gas Sensor Technology 

Features 

 
  • Range 0-20ppm SO2. 
  • Two stage alarm relays. 
  • Inbuilt test button. 
  • External pushbutton calibration. 
  • Inbuilt sensor diagnostics. 
  • Red 'alarm' LED. 
  • Green 'power on' LED. 
  • Internal audible sounder. 
  • Plug-in sensor. 
  • Remote audible/visual indicator unit. 
  • Protection to IP54. 
  • Optional PC interface module. 
  • Fault indication. 
  • Mains and dc powered versions available.
 

 
 
 
 

 
D-2-4, Setia Walk, Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia

Tel: + 6012-921 3877; 603-5879 7121
Fax: +018 635 1593
Email: ancor.my@gmail.com 
           sales@gasmonitors.com.my